  • Researchers in China have traced screen-printing degradation in copper-plated silicon heterojunction cells to wear of screen mesh knuckles and tested an emulsion buffer layer that limits direct wafer contact. A 4.7% coverage pattern reduced minority-carrier lifetime degradation to 0.41% after 10,000 cycles while preserving relatively good photoresist uniformity.
A conceptual cutaway of a screen-printing mesh, an emulsion buffer layer and a silicon heterojunction wafer, illustrating how modified screen contact could reduce mechanical stress during photoresist coating.

Researchers in China have investigated how screen printing for photoresist application can degrade copper-plated silicon heterojunction (HJT) solar cells and have proposed a modified screen design to reduce the damage. The work focuses on a step that differs from conventional silver-paste printing, where an emulsion-covered mesh limits contact with the wafer.

In full-area photoresist coating, screens are typically used without emulsion coverage so that resist can be deposited uniformly across the wafer. That exposes the wafer to direct and extensive contact with the mesh during every printing cycle. Corresponding author Lang Zhou said that in silver paste printing the screen openings occupy only 2–5% of the total area, while an emulsion layer covers the rest and prevents direct mesh-to-wafer contact.

Screen printing also involves mechanical pressure and thermal treatment that can damage sensitive passivating contacts, increasing recombination losses and reducing conversion efficiency. The researchers said earlier investigations in commercial production showed conversion efficiency falling from 26.2% to 25.7% over 15,000 consecutive printing cycles. Open-circuit voltage and fill factor accounted for most of the loss, while short-circuit current density and electrical resistance remained largely unchanged. Minority-carrier lifetime degradation rose from 0.61% with a new screen to 11.0% after 15,000 cycles.

Using 3D confocal microscopy, the team identified progressive wear of screen mesh knuckles as the main cause. As knuckles wore down, their contact area with the wafer increased, placing greater mechanical stress on the passivation layers. Scanning electron microscopy showed no visible surface scratches, but photoluminescence measurements indicated increased recombination losses, pointing to damage at the amorphous silicon/crystalline silicon interface.

To limit that contact, the researchers developed an emulsion buffer layer. They evaluated six patterns with emulsion coverage ratios from 2.9% to 16.6%. Higher coverage reduced mechanical damage but impaired photoresist distribution, revealing a trade-off between protection and coating uniformity. A 4.7% coverage ratio provided the best balance, limiting minority-carrier lifetime degradation to 0.41% after 10,000 printing cycles while maintaining relatively good coating uniformity.

The improvement was attributed to the emulsion layer preventing direct contact between the screen mesh and wafer, thereby reducing cumulative mechanical damage to the sensitive passivation layers.

Zhou said the findings showed that a relatively simple change to screen design can substantially mitigate printing-induced degradation and offer a practical route to improving manufacturing reliability for copper-plated HJT cells. The results were published in Solar Energy in the paper “Screen-printing photoresist induced efficiency degradation and mitigation in Cu-plated SHJ solar cells.”

The work adds to growing interest in copper metallization as an alternative to silver contacts in HJT cells. In April 2026, researchers at China’s Nankai University reported a silver-free HJT solar cell with 25.2% efficiency using plasma-induced interface engineering and copper electroplating; the approach addressed adhesion, contact resistance and stability challenges at the ITO interface. Separately, scientists at Germany’s Forschungszentrum Jülich achieved 23.08% efficiency in a fully copper-metallized HJT cell. That silver-free device showed a relatively small efficiency penalty compared with its silver-metallized counterpart, while cells combining silver-copper paste on the front and silver contacts on the rear reached 23.95%. The results underscore copper’s potential to reduce silver consumption, though further improvements in processing and electrical performance are still needed.